Back To Previous PagePHONE NUMBER
Sitemap

Flue Gas Analyzer- Model 1201A

Monitor Flue Stack Levels of O2, CO and Temperature

model 1201AOptimize combustion efficiency of your boiler, furnace or any commercial or industrial combustion process with the completely portable digital readout analyzer. The Model 1201A Flue Gas Analyzer features continuous readout of 02 concentrations and differential temperatures on LCD displays. A separate analog scale indicates carbon monoxide concentrations. Quickly perform calibration in the field for a variety of fuels. Each unit comes with a 10 5/8 inch (27 cm) stainless steel probe, 13 ft. (4 m) hose, replaceable particle/water filter, combustion efficiency charts, batteries and recharger, rugged carrying case and instruction manual.

No. 1201 A Flue gas analyzer
No. 1201-2 Replacement filter elements package of 3
No. 1201-5 220 VAC adapter
SUGGESTED SPECIFICATIONS

Range: O2: 0-25%,    CO: 400 PPM    Differential Temperature: 0-1100°
Accuracy: O2: ±2%,       CO: ±10%         Differential Temperature: ±1% of reading
Resolution: O2: 0.1%,      CO: 25 PPM      Differential Temperature: 1°F
Response Time: 12 seconds for 90% of reading
Operating Temperature: -32 to 104°F (0-40°C)
Storage Temperature: -32 to 104°F (0-40°C)
Probe: 105/8" (27 cm) length, stainless steel
Power: Rechargeable lead acid battery with 110 VAC adapter
Battery Life: 6 hours
Weight: 9.9 lbs. (4.5 kg)
Dimension: 8 ½" H x 15" W x 12 ½" D (22x38x32 cm)


Flue Gas Analyzer with Printer- Model 1201P

Automatically Calculates Combustion Efficiency

Model 1201P Model 470-1 Model 1201P

Model 1201P Flue Gas Analyzer allows complete analysis of combustion parameters to optimize burner efficiency for reduced cost operations and pollution emittance regulation. The instrument measures O2 CO and differential temperature and automatically calculates CO2, excess air, and combustion efficiency of five different fuels, including natural gas and propane. Built in printer provides a permanent record of measured and calculated values. Each unit comes complete with a 10 5/8 inch (27 cm) stainless steel probe, 13 feet (4 m) hose, replaceable particle/water filter, rechargeable battery and AC adapter, rugged carrying case, and instruction manual.

PHYSICAL DATA

Ranges: O2: 0-25%, CO: 0-1999 PPM CO2: 0-20% Differential
Temperature: 0-1100°F (-18 592°c), Efficiency: 0-100%
Accuracy: O2: ±0.2%, CO: ±10% of reading, CO2: ±0.2%
Differential Temperature: 1% or reading, Efficiency: ± 1%
Resolution: O2: 0.1%, CO: 1 PPM, CO2: 0.1%, Differential
Temperature: 1°F, Efficiency: 0.1%.
Response Time: 12 seconds for 90% of reading
Operating and Storage Temperature: -32 to 104°F (0-40°C)
Probe: 10 5/8 in. (27 cm) length, stainless steel
Power: Rechargeable lead acid battery with 110 VAC adapter
Battery Life: approximately 6 hours fully charged
Weight: 9.9 lbs. (4.5 kg)

ACCESSORY

No. 1201-2, Replacement filter element, package of 3