Back To Previous PagePHONE NUMBER
Sitemap

Differential Pressure Transmitter- Series 616

Ranges from 0-1 in. w.c. to 0-100 psid. Accuracy ±0.5% Full Span Output.

Series 616 Series 616

Series 616 Transmitters feature execptional ±0.5% accuracy in several factory calibrated ranges. Choose the one just right for your application. Span and Zero controls included for fine tuning and minor re-calibration in the field.

PHYSICAL DATA.
Pressure Connection: Barbed, dual size to fit 1/8" and 3/16" (3.2 and 4.8 mm) I.D. rubber or vinyl tubing
Media Compatibility: Air and compatible, non-corrosive, non-combustible gases
Electrical Connections: Screw-type terminal block
Housing: Black ABS plastic
Resistance: Potentiometers for zero and span
Weight: 2 oz. (57 g)
ELECTRICAL
Power Supply: 10-35 VDC (2, 3 or 4 wire), 16-26 VAC (4 wire)
Output Signal: 4-20 mA DC (limited at 38 mA DC)
Loop Resistance: DC: 0-1300 ohms maximumAC: 0-1200 ohms maximum
Current Consumption: DC: 38 mA maximum.AC: 76 mA maximum
PERFORMANCE AT 70°F (21°C)
Accuracy: ±0.5% F.S.O.
Zero Output: 4 mA DC
Full Span Output: 20 mA DC
Span and Zero: Adjustable to 0.05% of full span
Warm-up Time: 10 minutes
ENVIRONMENTAL
Operating Temperature: 20 to 120°F (-6.7 to 49°C)
Thermal Errors: ±0.02%/°F typical
MODULE MODELS
Model Number Range Maximum Pressure
616-00
616-0
616-1
616-2
616-3
616-4
607-5
607-6
616-7
0-1 in. w.c.
0-2 in. w.c.
0-3 in. w.c.
0-6 in. w.c.
0-10 in. w.c.
0-20 in. w.c.
0-40 in. w.c.
0-100 in. w.c.
0-200 in. w.c.
5 psig
5 psig
5 psig
5 psig
5 psig
11 psig
11 psig
29 psig
29 psig
Model Number Range Maximum Pressure
616-8
616-9
616-10
616-11
616-12
616-3B
616-6B
616-10B
616-20B
0-10 psid
0-20 psid
0-30 psid
0-50 psid
0-100 psid
1.5-0-1.5 in. w.c.
3-0-3 in w.c.
5-0-5 in. w.c.
10-0-10 in. w.c.
58 psig
58 psig
58 psig
150 psig
150 psig
5 psig
5 psig
5 psig
11 psig
- © FLW, Inc 1997- - S.D.G.