Back To Previous PagePHONE NUMBER
Sitemap

Wet/Wet Differential Pressure Transmitter- Series 645

4-20 mA signal. Two, three or four wire operation. Ranges to 6000 psi.

Series 634A Series 634A

Series 645 Wet/Wet Differential Pressure Transmitters are designed for use with compatible gases and liquids which can be applied to both the pressure and reference ports. Quick response capacitance sensor delivers a 4 to 20 mA output signal proportional to differential pressure with +/- 0.25% accuracy. The Series 645 transmitters are ideal for process control, filter condition monitoring, refrigeration equipment, pump speed control, HVAC equipment, and liquid level measurement.

PHYSICAL DATA.
Service: Compatible gases or liquids on both pressure and reference sides.
Output: 4 to 20 mA, 2-wire.
Supply Voltage: 11 to 30 VDC.
Loop Resistance: 0 to 1000W.
Zero and Span: Adjustable, non-interactive.
Max Line Pressure: 250 psig.
Max Overload Pressure: (High side) 1 to 5 psi: 20 x FS, 10 to 25 psi: 10 x FS, 50 psi: 5 x FS, 100 psi: 2.5 x FS; (Low side) 2-3 x FS.
Temperature Limits: Operating: 0 to 175°F (-22 to 80°C), Storage: -65 to 260°F (-54 to 126°C)
Accuracy: +/- 0.25% FS (RSS).
Response Time: 30 to 50 msec.
Thermal Effects: (includes zero and span) +/- 0.02% FS/°F, 30 to 150°F (-1 to 65°C).
Wetted Parts: 17-4 PH stainless steel, 300 Series stainless steel, Viton and Silicone O-rings and bleed screw seals.
Housing: Stainless steel/ Aluminum.
Process Connection: ¼" - 18 NPT(F).
Electrical Connection: Barrier strip terminal block with conduit enclosure and .875" (22mm) diameter conduit opening.
Weight: 14.4 oz (0.4 kg).
MODULE MODELS
Model Number Range Model Number Range
645-1
645-2
645-3
645-4
645-5
645-6
0 to 2 psid
0 to 5 psid
0 to 10 psid
0 to 25 psid
0 to 50 psid
0 to 100 psid
645-11
645-12
645-13
645-14
645-15
645-16
±1 psid
±2.5 psid
±5 psid
±10 psid
±25 psid
±50 psid
- © FLW, Inc 1997- - S.D.G.