Visible setpoint, adjustable deadband, pressure ranges to 5000 PSI.

Series DA/DS Series DA/DS

Customers tell us that this is the best pressure switch made. Our most popular, Model DA combines extremely high sensitivity and repeatability with easily adjustable set and reset points through non-interactive external adjustments. Visible calibrated dial for set points and on/off indicator to indicate switch actuation are included. Choose either high current snap-switch or hermetically sealed contact mercury switch. The DS Model has a fixed deadband.

FEATURES

  • DA Series is equipped with two external adjustments. One sets high pressure operating point, the other sets reset point. Deadband, or the difference between set and reset points is adjustable over the full scale. DS Series has a single external adjustment and fixed deadband.
  • Visible calibrated dial, on/off indication.
  • SPDT snap-action or sealed mercury switches.
  • Minimum deadband obtainable at any point in range.
  • Pressure Ranges vacuum to 5000 psig.
  • U.L. and C.S.A. Iisted. Many models FM listed.
PHYSICAL DATA


Max. temperature: 180°F. For higher temperature media applications, a remote connection or siphon (pigtail) should be used.
Pressure connection: 1/4" NPT. (1/2" on range 15S).
Housing: pressed steel with transparent cover.
Wiring connections: 3 screw type.
Wetted parts: same as Bourdon tube material.
Weight: 4 lb. (std); 6 Ib. (wea-proof); 8 Ib. (exp-proof).
Max. Press.: Max. adjustment operating range.

Suggested Specification
Pressure switch shall be Mercoid Series DA operated by a (brass) (type 316 stainless steel) (type 403 stainless steel) Bourdon tube actuating a (mercury switch) (snap-switch). Switch shall have deadband fixed or adjustable up to a maximum of 100% of switch range. Switch shall have calibrated dial and one or two pointers indicating set and reset points. Switch shall have visible on/off indication. Set points shall be adjustable without removing switch cover or shutting down process.

MODEL & RANGE CHARTS

Bourdon Tube Material Adjustable Operating Range (PSIG) Mercury Switch - SPDT
4A@120V., 2A@240v., AC/DC
Snap Action Switch -
SPDT 15A@120/240 VAC
Snap Action Switch -
SPDT 15A@120/240 VAC
Minimum Deadband PSIG Model Number Minimum Deadband PSIG Model Number Fixed Deadband PSIG Model Number
Brass 0-30" Hg. Vac. 2" Hg. Vac DA-31-153-2* 9"Hg. Vac. DA-7031-153-2* 3" Hg. Vac. DS-7231-153-2*
1/8-15 1 DA-31-153-1 4 DA-7031-153-1 1.5 DS-7231-153-1
1/8-20 1 DA-31-153-3A 4 DA-7031-153-3A 1.5 DS-7231-153-3A
1-35 1.75 DA-31-153-4 5 DA-7031-153-4 1.5 DS-7231-153-4
2-60 3 DA-31-153-5 6 DA-7031-153-5 2 DS-7231-153-5
5-100 3.75 DA-31-153-6 9 DA-7031-153-6 2.5 DS-7231-153-6
5-150 6 DA-31-153-7 16 DA-7031-153-7 3 DS-7231-153-7
10-200 8 DA-31-153-8 16 DA-7031-153-8 4 DS-7231-153-8
10-300 14 DA-31-153-9 25 DA-7031-153-9 5 DS-7231-153-9
403SS 2-60 4 DA-21-153-5S 9 DA-7021-153-5S 3 DS-7221-153-5S
5-100 6 DA-21-153-6S 13 DA-7021-153-6S 3.5 DS-7221-153-6S
10-200 8 DA-21-153-8S 15 DA-7021-153-8S 4 DS-7221-153-8S
10-300 14 DA-21-153-9S 19 DA-7021-153-9S 6 DS-7221-153-9S
25-600 25 DA-21-153-10S 45 DA-7021-153-10S 10 DS-7221-153-10S
100-1500 90 DA-21-153-12S 130 DA-7021-153-12S 30 DS-7221-153-12S
500-5000 450 DA-21-153-15S* 900 DA-7021-153-15S* 200 DS-7221-153-15S*
316SS 10-150 6 DA-41-153-24E 11 DA-7041-153-24E 4 DS-7241-153-24E
10-300 18 DA-41-153-9E 28 DA-7041-153-9E 8 DS-7241-153-9E

Additional features available on special order, include other electrical ratings and circuits, lower minimum differentials, special housings, diaphragm seals and manual reset. For severe vibration, a special Delrin Bushed Movement is available.

* Range 2 and 15S not FM approved. Other ranges FM approved. For FM approved models specify DAF or DSF. Example DAF-31-153-1.


High Current Capacity§ or Extra Low Deadband Mercury Switch (SPST)§

Bourdon Tube Material Adjustable Operating Range (PSIG) Mercury Switch - SPST - High Current
10A@120V., 5A@240v., AC/DC
Mercury Switch - SPST - Low Deadband
5A@120VC. 2A@240 VAC., 2.5A@120VDC
Minimum
Deadband PSIG
OPEN on Inc.
Model Number
CLOSE on Inc.
Model Number
Minimum
Deadband PSIG
OPEN on Inc.
Model Number
CLOSE on Inc.
Model Number
Brass 0-30" Hg. Vac. 2" Hg. Vac DA-31-2-2* DA-31-3-2* 1" Hg. Vac. DA-531-2-2* DA-531-3-2*
1/8-15 1 DA-31-2-1 DA-31-3-1 0.5 DA-531-2-1 DA-531-3-1
1/8-20 1 DA-31-2-3A DA-31-3-3A 0.5 DA-531-2-3A DA-531-3-3A
1-35 1.75 DA-31-2-4 DA-31-3-4 0.75 DA-531-2-4 DA-531-3-4
2-60 3 DA-31-2-5 DA-31-3-5 1.0 DA-531-2-5 DA-531-3-5
5-100 3.75 DA-31-2-6 DA-31-3-6 2.0 DA-531-2-6 DA-531-3-6
5-150 6 DA-31-2-7 DA-31-3-7 3.0 DA-531-2-7 DA-531-3-7
10-200 8 DA-31-2-8 DA-31-3-8 3.5 DA-531-2-8 DA-531-3-8
10-300 14 DA-31-2-9 DA-31-3-9 6.0 DA-531-2-9 DA-531-3-9
403SS 2-60 4 DA-21-2-5S DA-21-3-5S 2.5 DA-521-2-5S DA-521-3-5S
5-100 6 DA-21-2-6S DA-21-3-6S 3.0 DA-521-2-6S DA-521-3-6S
10-200 8 DA-21-2-8S DA-21-3-8S 4.0 DA-521-2-8S DA-521-3-8S
10-300 14 DA-21-2-9S DA-21-3-9S 7 DA-521-2-9S DA-521-3-9S
25-600 25 DA-21-2-10S DA-21-3-10S 15 DA-521-2-10S DA-521-3-10S
100-1500 90 DA-21-2-12S DA-21-3-12S 50 DA-521-2-12S DA-521-3-12S
500-5000 450 DA-21-2-15S* DA-21-3-15S* 200 DA-521-2-15S* DA-521-3-15S*
316SS 10-150 6 DA-41-2-24E DA-41-3-24E 3.0 DA-541-2-24E DA-541-3-24E
10-300 18 DA-41-2-9E DA-41-3-9E 5.0 DA-541-2-9E DA-541-3-9E

§ Also available in Weather-proof (DAW-33) or Explosion-proof (DAH-31) Housings.

* Range 2 and 15S not FM approved. Other ranges FM approved. For FM approved models specify DAF or DSF. Example: DAF-31-2-1.


Weather-proof Models

Bourdon Tube Material Adjustable Operating Range (PSIG) Mercury Switch - SPDT
4A@120V., 2A@240V., AC/DC
Snap Action Switch -
SPDT 15A@120/240 VAC
Snap Action Switch -
SPDT 15A@120/240 VAC
Minimum Deadband PSIG Model Number Minimum Deadband PSIG Model Number Fixed Deadband PSIG Model Number
Brass 0-30" Hg. Vac. 2" Hg. Vac DAW-33-153-2* 9" Hg. Vac. DAW-7033-153-2* 3" Hg. Vac. DSW-7233-153-2*
1/8-15 1 DAW-33-153-1 4 DAW-7033-153-1 1.5 DSW-7233-153-1
1/8-20 1 DAW-33-153-3A 4 DAW-7033-153-3A 1.5 DSW-7233-153-3A
1-35 1.75 DAW-33-153-4 5 DAW-7033-153-4 1.5 DSW-7233-153-4
2-60 3 DAW-33-153-5 6 DAW-7033-153-5 2 DSW-7233-153-5
5-100 3.75 DAW-33-153-6 9 DAW-7033-153-6 2.5 DSW-7233-153-6
5-150 6 DAW-33-153-7 16 DAW-7033-153-7 3 DSW-7233-153-7
10-200 8 DAW-33-153-8 16 DAW-7033-153-8 4 DSW-7233-153-8
10-300 14 DAW-33-153-9 25 DAW-7033-153-9 5 DSW-7233-153-9
403SS 2-60 4 DAW-23-153-5S 9 DAW-7023-153-5S 3 DSW-7223-153-5S
5-100 6 DAW-23-153-6S 13 DAW-7023-153-6S 3.5 DSW-7223-153-6S
10-200 8 DAW-23-153-8S 15 DAW-7023-153-8S 4 DSW-7223-153-8S
10-300 14 DAW-23-153-9S 19 DAW-7023-153-9S 6 DSW-7223-153-9S
25-600 25 DAW-23-153-10S 45 DAW-7023-153-10S 10 DSW-7223-153-10S
100-1500 90 DAW-23-153-12S 130 DAW-7023-153-12S 30 DSW-7223-153-12S
500-5000 450 DAW-23-153-15S* 900 DAW-7023-153-15S* 200 DSW-7223-153-15S*
316SS 10-150 6 DAW-43-153-24E 11 DAW-7043-153-24E 4 DSW-7243-153-24E
10-300 18 DAW-43-153-9E 28 DAW-7043-153-9E 8 DSW-7243-153-9E

* Range 2 and 15S not FM approved. All other DAW ranges are FM approved.