Series RMV II Rate-Master Flowmetersemploy a target-type design combined with a damage resistant magnetic linkage to drive a pointer over an easy-to-read litho scale. This unique construction fully isolates flowing media from gage front for leakproof operation at pressures to 3000 psig (206.7 bar) with +/- 5% of full scale accuracy. Solid machined brass meter body is ideally suited for water flows. Body design fits standard 4 ½" mounting hold layouts pe ANSI B40.1. Inlet and outlet threads are standard ¾" NPT female.
| Meter Body: | Brass |
|---|---|
| Dial Face Case: | Molded polycarbonate |
| Finish: | Uncoated brass and black polycarbonate |
| Front Cover: | Clear cast acrylic |
| Wetted Parts: | Brass, 302SS, sintered barium ferrite, polyacetyl |
| O-Rings: | Buna-N |
| Connections: | ¾" NPT female |
| Maximum Temperature: | 200°F (93°C) |
| Accuracy: | +/- 5% of full scale |
| Maximum Pressure: | 3000 psig (206 bar) |
| Flow Direction: | Left to right |
| Weight: | 2 lbs., 14 oz. (1.3 kg) |
| Model Number | Range, GPM Water |
|---|---|
| RMVII-1 RMVII-3 RMVII-6 |
0-3 0-5 0-10 |