Shaft drive and 1 inch long bushing with O-ring seal provide protection against contamination in industrial environments.
Adjustable windows (56° range/90° fixed), in stainless steel visual indicators show OPEN, CLOSED and °s (0-90) in 5° increments on inner drum, also adjustable in 15° increments.
- UL & CSA listed Class I, Groups A, B, C, D; Class II, Groups E, F, G; Division 1 & 2
- Designed to meet NEMA 1,2,3,3R,3S,4,4X,6,6P,7,9,12,13.
- EZSet™ adjustable cams actuate mechanical or proximity switch(es). The simple, single-step rotational cam adjustment includes locking set screw.
- Available with potentionmeter or 4-20 mA transmitter.
- Housing options: anodized aluminum, triple epoxy coated aluminum or stainless steel with up to 3 conduit entrances in housing base.
- Visual indicator standard for direct drive, automated quarter turn.
- Standard operating temperature: -65°F to 180°F (-54° C to 82° C).