• Features
  • Ordering Information
  • Specifications
  • Alternating Rate/Total Display
  • 0.5" High Display
  • 4-20 mA Input
  • Linear or Square Root Input
  • Field Selectable Noise Filtering
  • Low Flow Cutoff
  • Non-volatile Memory, No Battery Needed
  • Isolated Open Collector Pulse Output
  • Loop-powered Backlighting Option
PD696 PD696 PD696
Model PD696 photo Model PD697 photo Model PD698 photo
Model: Description:
   PD696-N Panel mount Loop-powered Totalizer
   PD696-B Panel mount Loop-powered Totalizer
with Loop-powered Backlighting Option
   PD697-N NEMA 4X Loop-powered Totalizer
   PD697-B NEMA 4X Loop-powered Totalizer
with Loop-powered Backlighting Option
   PD698-N Explosion-proof Loop-powered Totalizer
   PD698-B Explosion-proof Loop-powered Totalizer
with Loop-powered Backlighting Option
OPTIONS:
Model: Description:
   PDA6844 NEMA 4X Panel Mounting Kit
   PDA6845 2" Pipe Mounting Kit
  • INPUT: 4-20 mA, linear or square root.
  • DISPLAY: Sharp, 0.5" (12.7mm) high LCD, 6 digits; Rate: 0 to 19,999. Total: 0 to 999,999. Automatic lead zero blanking, user selectable decimal point.
  • ALTERNATING DISPLAY: Display may be programmed to alternate between rate and total every 10 seconds.
  • MAXIMUM INPUT CURRENT: 30 mA
  • MAXIMUM VOLTAGE DROP: 5.6 VDC @ 20 mA without backlighting; 7.0 VDC @ 20 mA with backlighting option.
  • CALIBRATION RANGE: 4 mA input may be set anywhere in range of the meter. 20 mA may be set anywhere in range of the meter above or below 4 mA input.
  • ACCURACY: 0.05% of calibrated span, +/-1 count.
  • SQUARE ROOT EXTRACTION ACCURACY: +/-0.1% F.S. +/-1 count from 10-100% of flow.
  • MINIMUM INPUT SPAN: 1.6 mA between points.
  • LOW FLOW CUTOFF: 1 count to 100% F.S., user selectable. To disable low flow cutoff, program cutoff value to zero.
  • NOISE FILTER: The field selectable noise filter allows the meter to be programmed so that an unsteady (noisy) input can be displayed with greater stability.
  • NON-VOLATILE MEMORY: All programming values are stored in non-volatile memory for a minimum of ten years if power is lost. No battery required.
  • TOTALIZER: Calculates total based on rate and field programmable multiplier to display total in any engineering units.
  • TOTAL RESET: Via front panel ENTER button or external contact closure at terminals R and CM.
  • ROLL OVER: Totalizer "rolls over" when display exceeds 999,999.
  • ISOLATED OPEN COLLECTOR PULSE OUTPUT: Circuit produces 1 pulse per a given number of counts; User selectable from 1 pulse per count to 1 pulse per 999 counts.
  • PULSE OUTPUT RATING: 24 VDC @ 20 mA
  • LOCKOUT: Jumper at rear of instrument restricts modification of calibration values.
  • CONNECTIONS: Removable screw terminal block (provided).
  • OPERATING TEMPERATURE: 0 to 65oC
  • PD696 ENCLOSURE: 1/8 DIN, high impact plastic, UL 94V-O; Front panel, NEMA 4X, panel gasket provided.
  • PD697 ENCLOSURE: High impact-resistant polycarbonate body and cover; NEMA 4X; 1/2" conduit hole provided at base. May be provided on back for panel mounting applications, call factory for details.
  • PD698 ENCLOSURE: Cast aluminum, approved by FM and CSA; NEMA 4, 7 & 9; Class I, Groups B, C & D and Class II, Groups E, F, & G. Two 3/4" NPT holes provided.