• Features
  • Ordering Information
  • Specifications
  • Options
  • Signal & Power Connections
Model PD750
Model PD751
Model PD752
  • Handles Thermocouple and RTD Inputs
  • J,K,T,E,R, & S Thermocouples
  • Platinum RTD (0.00385 or 0.00392 curve)
  • Type T T/C and RTD's displayed to 0.1o
  • Display F or C
  • NEMA 4X Front Panel
  • 2 or 4 Relays + 4-20 mA Output Option
  • Scan multiple inputs with the PD118
  • 10 ohm Copper RTD Input
  • Display F or C to 0.1o
  • NEMA 4X Front Panel
  • 2 or 4 Relays + 4-20 mA Output Option
  • 120 ohm Nickel RTD Input
  • Displays F or C to 0.1o
  • NEMA 4X Front Panel
  • 2 or 4 Relays + 4-20 mA Output Option
All Models

4 Visual Alarms Standard

  • Front Panel Alarm Status Indicator
  • Perfect for Visual-indication-only Applications
  • Any Combination of High or Low Set Points
  • 0-100% Deadband Adjustment
Model: Description:
115 VAC
   *PD750-3-N
   *PD750-3-14
   *PD750-3-15
   PD750-3-16
   PD750-3-17
   PD750-3-18
230 VAC
   PD750-4-N
   PD750-4-14
   PD750-4-15
   PD750-4-16
   PD750-4-17
   PD750-4-18

No Options
2 Relays
4-20 mA Output
2 Relays + 4-20 mA Output
4 Relays
4 Relays + 4-20 mA Output
18-36 VDC
   PD750-2-N
   PD750-2-14
   PD750-2-15
   PD750-2-16
   PD750-2-17
   PD750-2-18

No Options
2 Relays
4-20 mA Output
2 Relays + 4-20 mA Output
4 Relays
4 Relays + 4-20 mA Output
115 VAC
PD751-3-N
PD751-3-14
PD751-3-15
PD751-3-16
PD751-3-17
PD751-3-18
230 VAC
   PD751-4-N
   PD751-4-14
   PD751-4-15
   PD751-4-16
   PD751-4-17
   PD751-4-18
10 ohm Copper RTD
No Options
2 Relays
4-20 mA Output
2 Relays + 4-20 mA Output
4 Relays
4 Relays + 4-20 mA Output
18-36 VDC
   PD751-2-N
   PD751-2-14
   PD751-2-15
   PD751-2-16
   PD751-2-17
   PD751-2-18

No Options
2 Relays
4-20 mA Output
2 Relays + 4-20 mA Output
4 Relays
4 Relays + 4-20 mA Output
115 VAC
   PD752-3-N
   PD752-3-14
   PD752-3-15
   PD752-3-16
   PD752-3-17
   PD752-3-18
230 VAC
   PD752-4-N
   PD752-4-14
   PD752-4-15
   PD752-4-16
   PD752-4-17
   PD752-4-18
120 ohm Nickel RTD
No Options
2 Relays
4-20 mA Output
2 Relays + 4-20 mA Output
4 Relays
4 Relays + 4-20 mA Output
18-36 VDC
   PD752-2-N
   PD752-2-14
   PD752-2-15
   PD752-2-16
   PD752-2-17
   PD752-2-18

No Options
2 Relays
4-20 mA Output
2 Relays + 4-20 mA Output
4 Relays
4 Relays + 4-20 mA Output

Basic Meter
  • INPUTS: Field selectable: type J,K,T,E,R, or S thermocouples with 1o resolution; type T to 0.1o; 100 ohm platinum (0.00385 or 0.00392 curve), 10 ohm copper or 120 ohm nickel RTDs with 1o or 0.1o resolution.
  • DISPLAY: Bright, large, 0.56" (14.2mm) high efficiency red or green LED, 41/2 digits. F or C may be switched on to indicate Fahrenheit or Celsius.
  • COLD JUNCTION REFERENCE: Automatic, fixed, no user calibration needed.
  • T/C OPEN INDICATION: Open thermocouple circuit indicated by flashing display. Status of relays determined by setting.
  • HOLD READING: Connect switch to ACK/HLD and COM terminals, also connect jumper pins at rear.
  • INPUT IMPEDANCE: Greater than 100 Kohms.
  • NON-VOLATILE MEMORY: All programming values are stored in non-volatile memory for ten years if power is lost.
  • POWER:
AC power: 115 VAC +/-10%, 50/60 Hz, 10VA.
230 VAC +/-10%, 50/60 Hz, 10VA.
DC power: 18-36 VDC, 6 watts max.
  • ENCLOSURE: 1/8 DIN, high impact plastic, UL 94V-0.
  • FRONT PANEL: NEMA 4X, panel gasket provided.
  • CONNECTIONS: Removable screw terminal block (provided), accepts 24 to 12 AWG.
  • ALARM POINTS: 4, any combination of high or low alarms.
  • ALARM STATUS INDICATION: Front panel LED
  • ALARM DEADBAND:> 0-100% of full scale, field selectable.
  • UL FILE NUMBER: E160849; 508 Industrial Control Equipment. (PD750 only).
Relays
  • RATING: 2 or 4 relays; 2 Amp SPDT (form C). The contacts are rated 2 Amp @ 30 VDC or 2 Amp @ 250 VAC resistive load; 1/14 HP @ 125 / 250 VAC for NC contacts and 1/10 HP @ 125 / 250 VAC for NO contacts, inductive load.
  • RESET: User Select.
  • 1. Automatically when the input passes the reset point. 2. Automatically + manually (via user supplied switch or front panel ACK button).
  • FAILSAFE OPERATION: The relay coils are energized in the non-alarm condition. In the case of a power failure, the relays will go to the alarm state. May be disabled with internal jumper.
  • AUTO INITIALIZATION: When power is applied to the meter, the relays will always reflect the state of the input to the meter.
  • DEADBAND: 0-100%, User Selectable.
Isolated 4-20 mA Transmitter Output
  • CALIBRATION RANGE: Anywhere in range of meter, 501 count minimum span.
  • OUTPUT LOOP RESISTANCE:
Loop Resistance
Power Supply Min Max
24 VDC 10 ohm 600 ohm
36 VDC (external) 600 ohm 1000 ohm
  • EXTERNAL LOOP POWER SUPPLY: 35 V max.
  • ACCURACY: +/-0.1% FS, +/-004 mA.
  • ISOLATION: 500 VDC or peak AC, input-to-input or input/output-to-power line.
2 or 4 Relays
  • 2 or 4 SPDT, 2 amps @ 250 VAC Resistive Load
  • Automatic or Automatic + Manual Reset
  • Failsafe Action & Auto Initialization
  • 0-100% Deadband Adjustment
Isolated 4-20 mA Transmitter Output
  • 4-20 mA or 20-4 mA Output
  • 500 VDC Isolation
  • Can be Scaled over Narrow Range
  • With or Without Relay Contacts
The PD750, equipped with the isolated 4-20 mA output signal option turns the unit into a temperature transmitter with a digital display. This 4-20 mA signal is linearized, cold junction compensated and may be scaled for practically any range.
  • PD750 Four Wire RTD Connections
  • PD750 Three Wire RTD Connections
  • PD750 TwoWire RTD Connections
  • PD750 Thermocouple Connections
PD750-3-15.jpg (9182 bytes)
Pre-calibrated Ranges
Input: Range: Accuracy:
Type J -328o to 1382oF
-200o to 750oC
+/-1.4oF
+/-0.8oC
Type K -328o to 2498oF
-200o to 1330oC
+/-1.7oF
+/-0.9oC
Type T -328o to 2498oF
-200o to 750oC
+/-1.5oF
+/-0.8oC
Type E -328o to 2498oF
-200o to 750oC
+/-1.4oF
+/-0.8oC
Type R -328o to 2498oF
-200o to 750oC
+/-4.8oF
+/-2.7oC
Type S -328o to 2498oF
-200o to 750oC
+/-5.7oF
+/-2.9oC
100 ohm Pt RTD -328o to 2498oF
-200o to 750oC
+/-0.6oF
+/-0.3oC
10 ohm Cu RTD -328o to 2498oF
-200o to 750oC
+/-0.2oF
+/-0.1oC
120 ohm Ni RTD -328o to 2498oF
-200o to 750oC
+/-0.2oF
+/-0.1oC
quotation
North California Office :- 285-A Bel Marin Keys Blvd - Novato, CA - 94949 PH: (415) 382 - 9710 FAX: (415) 382 - 9720
- © FLW, Inc 1997- - S.D.G.