Model PD751, PD752, & PD753 |
 |
Precision Digital's Universal Temperature
Meters handle temperature displaying, alarming and re-transmitting applications with
simplicity, accuracy and reliability. The PD750 is available with up to 4 relays, isolated
4-20 mA output, and is factory programmed for easy field selection of the thermocouple or
RTD type. Just select your input type (J,K,T,E,R,S thermocouple or 100 ohm RTD), and
either Fahrenheit or Celsius and connect the sensor. The PD751 accepts 10 ohm copper while
the PD752 accepts 120 ohm nickel RTD inputs.
Features  
Specifications  
Order Info

Shown with optional green display |
Features / Options
Models PD750 - PD751 - PD752 - All Models
| Model PD750 |
- Handles Thermocouple and RTD Inputs
- J,K,T,E,R, & S Thermocouples
- Platinum RTD (0.00385 or 0.00392 curve)
- Type T T/C and RTD's displayed to 0.1o
- Display F or C
- NEMA 4X Front Panel
- 2 or 4 Relays + 4-20 mA Output Option
- Scan multiple inputs with the PD118
|
| Model PD751 |
- 10 ohm Copper RTD Input
- Display F or C to 0.1o
- NEMA 4X Front Panel
- 2 or 4 Relays + 4-20 mA Output Option
|
| Model PD752 |
- 120 ohm Nickel RTD Input
- Displays F or C to 0.1o
- NEMA 4X Front Panel
- 2 or 4 Relays + 4-20 mA Output Option
|
All Models
4 Visual Alarms Standard
- Front Panel Alarm Status Indicator
- Perfect for Visual-indication-only Applications
- Any Combination of High or Low Set Points
- 0-100% Deadband Adjustment
2 or 4 Relays
- 2 or 4 SPDT, 2 amps @ 250 VAC Resistive Load
- Automatic or Automatic + Manual Reset
- Failsafe Action & Auto Initialization
- 0-100% Deadband Adjustment
Isolated 4-20mA Transmitter Output
- 4-20 mA or 20-4 mA Output
- 500 VDC Isolation
- Can be Scaled over Narrow Range
- With or Without Relay Contacts
|
The PD750, equipped with the isolated 4-20 mA output signal option turns the unit into
a temperature transmitter with a digital display. This 4-20 mA signal is linearized, cold
junction compensated and may be scaled for practically any range.
Signal & Power Connections
- PD750 Four Wire RTD Connections
- PD750 Three Wire RTD Connections
- PD750 TwoWire RTD Connections
- PD750 Thermocouple Connections
Pre-calibrated Ranges
| Input: |
Range: |
Accuracy: |
| Type J |
-328o to 1382oF
-200o to 750oC |
+/-1.4oF
+/-0.8oC |
| Type K |
-328o to 2498oF
-200o to 1330oC |
+/-1.7oF
+/-0.9oC |
| Type T |
-328o to 2498oF
-200o to 750oC |
+/-1.5oF
+/-0.8oC |
| Type E |
-328o to 2498oF
-200o to 750oC |
+/-1.4oF
+/-0.8oC |
| Type R |
-328o to 2498oF
-200o to 750oC |
+/-4.8oF
+/-2.7oC |
| Type S |
-328o to 2498oF
-200o to 750oC |
+/-5.7oF
+/-2.9oC |
| 100 ohm Pt RTD |
-328o to 2498oF
-200o to 750oC |
+/-0.6oF
+/-0.3oC |
| 10 ohm Cu RTD |
-328o to 2498oF
-200o to 750oC |
+/-0.2oF
+/-0.1oC |
| 120 ohm Ni RTD |
-328o to 2498oF
-200o to 750oC |
+/-0.2oF
+/-0.1oC |
Top  
Features  
Specifications  
Order Info
| Model: |
|
Description: |
115 VAC
*PD750-3-N
*PD750-3-14
*PD750-3-15
PD750-3-16
PD750-3-17
PD750-3-18 |
230 VAC
PD750-4-N
PD750-4-14
PD750-4-15
PD750-4-16
PD750-4-17
PD750-4-18 |
No Options
2 Relays
4-20 mA Output
2 Relays + 4-20 mA Output
4 Relays
4 Relays + 4-20 mA Output |
18-36 VDC
PD750-2-N
PD750-2-14
PD750-2-15
PD750-2-16
PD750-2-17
PD750-2-18 |
|
No Options
2 Relays
4-20 mA Output
2 Relays + 4-20 mA Output
4 Relays
4 Relays + 4-20 mA Output |
115 VAC
PD751-3-N
PD751-3-14
PD751-3-15
PD751-3-16
PD751-3-17
PD751-3-18 |
230 VAC
PD751-4-N
PD751-4-14
PD751-4-15
PD751-4-16
PD751-4-17
PD751-4-18 |
10 ohm Copper RTD
No Options
2 Relays
4-20 mA Output
2 Relays + 4-20 mA Output
4 Relays
4 Relays + 4-20 mA Output |
18-36 VDC
PD751-2-N
PD751-2-14
PD751-2-15
PD751-2-16
PD751-2-17
PD751-2-18 |
|
No Options
2 Relays
4-20 mA Output
2 Relays + 4-20 mA Output
4 Relays
4 Relays + 4-20 mA Output |
115 VAC
PD752-3-N
PD752-3-14
PD752-3-15
PD752-3-16
PD752-3-17
PD752-3-18 |
230 VAC
PD752-4-N
PD752-4-14
PD752-4-15
PD752-4-16
PD752-4-17
PD752-4-18 |
120 ohm Nickel RTD
No Options
2 Relays
4-20 mA Output
2 Relays + 4-20 mA Output
4 Relays
4 Relays + 4-20 mA Output |
18-36 VDC
PD752-2-N
PD752-2-14
PD752-2-15
PD752-2-16
PD752-2-17
PD752-2-18 |
|
No Options
2 Relays
4-20 mA Output
2 Relays + 4-20 mA Output
4 Relays
4 Relays + 4-20 mA Output |
Top  
Features  
Specifications  
Order Info
Basic Meter
- INPUTS: Field selectable: type J,K,T,E,R, or S thermocouples
with 1o resolution; type T to 0.1o; 100 ohm platinum
(0.00385 or 0.00392 curve), 10 ohm copper or 120 ohm nickel RTDs with 1o
or 0.1o resolution.
- DISPLAY: Bright, large, 0.56" (14.2mm) high efficiency red
or green LED, 41/2 digits. F or C may be switched on to indicate Fahrenheit or Celsius.
- COLD JUNCTION REFERENCE: Automatic, fixed, no user calibration
needed.
- T/C OPEN INDICATION: Open thermocouple circuit indicated by
flashing display. Status of relays determined by setting.
- HOLD READING: Connect switch to ACK/HLD and COM terminals, also
connect jumper pins at rear.
- INPUT IMPEDANCE: Greater than 100 Kohms.
- NON-VOLATILE MEMORY: All programming values are stored in non-volatile
memory for ten years if power is lost.
- POWER:
|
AC power: |
115 VAC +/-10%, 50/60 Hz, 10VA.
230 VAC +/-10%, 50/60 Hz, 10VA. |
|
DC power: |
18-36 VDC, 6 watts max. |
- ENCLOSURE: 1/8 DIN, high impact plastic, UL 94V-0.
- FRONT PANEL: NEMA 4X, panel gasket provided.
- CONNECTIONS: Removable screw terminal block (provided), accepts
24 to 12 AWG.
- ALARM POINTS: 4, any combination of high or low alarms.
- ALARM STATUS INDICATION: Front panel LED
- ALARM DEADBAND:> 0-100% of full scale, field selectable.
- UL FILE NUMBER: E160849; 508 Industrial Control Equipment. (PD750 only).
Relays
- RATING: 2 or 4 relays; 2 Amp SPDT (form C). The contacts are
rated 2 Amp @ 30 VDC or 2 Amp @ 250 VAC resistive load; 1/14 HP @ 125 / 250 VAC for NC
contacts and 1/10 HP @ 125 / 250 VAC for NO contacts, inductive load.
- RESET: User Select.
1. Automatically when the input passes the reset point.
2. Automatically + manually (via user supplied switch or front panel ACK button).
- FAILSAFE OPERATION: The relay coils are energized in the
non-alarm condition. In the case of a power failure, the relays will go to the alarm
state. May be disabled with internal jumper.
- AUTO INITIALIZATION: When power is applied to the meter, the
relays will always reflect the state of the input to the meter.
- DEADBAND: 0-100%, User Selectable.
Isolated 4-20 mA
Transmitter Output