Model PD650
The PD650 Large Display Universal Process Meter features 2.3" high digits housed in a rugged die cast aluminum NEMA 4X enclosure. The PD650 accepts the common process signals such as 4-20 mA, 0-5 VDC, and 0-10 VDC. It has all the features of the PD690 as well as a few new ones: dual 24 volt isolated power supplies for both the input and output loops and built-in relay suppression for more consistent relay operation. The PD650 can also function as a flow rate/totalizer, operating like our PD692. Features include: alternating rate/total display, programmable time base of second, minute or hour, automatic total reset, square root extraction, and many more. Large Display Universal Process Meter
Features   Specifications   Order Info
Features
- Large 2.3" High LEDs
- 4-1/2 Digit + Extra Zero Display for Rate
- 6 Digit Display for Total
- 4-20 mA, 0-5 V, or 0-10 V Field Selectable Inputs
- Dual 24 VDC Isolated Power Supply
- NEMA 4X Die Cast Aluminum Enclosure
- All the Features of the PD690 Plus the PD692
- 2 or 4 Relay Option with Built-in Suppression
- 4-20 mA Output Option
- 115 or 230 VAC Powered, Field Select
Top   Features   Specifications   Order Info
Ordering Information
Model: Description: PD650-N No Options PD650-34 2 Relays PD650-35 4-20 mA Output PD650-36 2 Relays + 4-20 mA Output PD650-37 4 Relays PD650-38 4 Relays + 4-20 mA Output Top   Features   Specifications   Order Info
Specifications
- INPUTS: Field selectable: 4-20 mA, 0-20 mA, 0-5 V, 1-5 V, 0-10 V.
- DISPLAY: 6 digit, 2.3" (58mm) high efficiency red LED. Rate: 0 to 29,999(0) with selectable extra zero. Total: 0 to 999,999. Automatic lead zero blanking.
- LINEAR INPUT ACCURACY: 0.05% of calibrated span, +/- 1 count.
- SQUARE ROOT EXTRACTION ACCURACY: +/-0.1% F.S. +/-1 count from 10-100% of flow.
- INPUT IMPEDANCE: Voltage ranges, greater than 300 Kohm; current ranges, 100 ohm.
- CALIBRATION: May be calibrated using internal calibration or by applying an external calibration signal.
- CALIBRATION RANGE: 4 mA (1 V) input may be set anywhere in range of the meter. 20 mA (5 V) may be set anywhere in range of the meter, above or below 4 mA (1V) input.
- MINIMUM INPUT SPAN: 1.6 mA between points.
- LOOP POWER: Isolated, up to 20 mA at 24 VDC regulated +/-5%, noise less than 10 mVpp. Max. loop resistance of 1200 ohm. Dual outputs can power both an external transmitter and 4-20 mA output signal.
- NON-VOLATILE MEMORY: All programming values are stored in non-volatile memory for ten years if power is lost.
- LOCKOUT: Jumper inside instrument restricts modification of calibration values.
- POWER: AC power: 115 or 230 VAC (field Select) +/-10%, 50/60 Hz,12 VA.
- ENVIRONMENTAL: Operating temperature range: 0 to 65¡C
- ENCLOSURE: Die Cast Aluminum, NEMA 4X; Four 1/2" conduit holes provided at base. Mounting: Enclosure contains four 1/4" holes for wall-mounting.
- CONNECTIONS: Removable screw terminal block (provided).
- RELAY RATINGS: 2 or 4 SPDT (form C); rated 2 Amp @ 30 VDC or 2 Amp @250 VAC resistive load; 1/14 HP @ 125 / 250 VAC for inductive loads. Built-in suppression.
Top   Features   Specifications   Order Info